    A former coworker was abroad most of the time. Still, his power meter showed lots of usage during his absence. A tenant in the same house had used such a cord to leech power across the common laundry room.

    Now that coworker knew his way about electricity. So instead of the 220V between common and a phase, he rewired his washing machine socket to two different phases, aka 380V, and left for a week.

    When he came back, he saw a number of kitchen- and other appliances waiting for trash collection.

      • Treczoks@lemmy.world
        link
        fedilink
        arrow-up
        2
        ·
        1 day ago

        Absolutely normal here. Three phases, now 400 instead of 380V back then, 64A. Standard house connection.

        • FourWaveforms@lemm.ee
          link
          fedilink
          arrow-up
          2
          ·
          18 hours ago

          In the States the new standard is 240V @ 200 amps, split phase. Most circuits are half of a phase (120V) but there are 240V circuits for load-heavy appliances like stoves and air conditioning. I’ve heard some people have an extra 240V socket in their kitchens just for tea kettles.

          • Treczoks@lemmy.world
            link
            fedilink
            arrow-up
            1
            ·
            8 hours ago

            These-phase 400V is the standard house connection here in Europe. Wall sockets are 240V/16A (any phase to neutral), but we also have devices running on three phases, like the oven or the geyser in the kitchen.

  • A_Random_Idiot@lemmy.world
    link
    fedilink
    English
    arrow-up
    18
    ·
    2 days ago

    “this time of year” is 100% christmas.

    from people putting up lights, probably trying to run remote power to a box with an extension cord, or because they installed half their lights backward and need this to bridge between the two sets because they rather embrace the danger than redo all the work.

  • Steal Wool@lemm.ee
    link
    fedilink
    English
    arrow-up
    15
    arrow-down
    2
    ·
    2 days ago

    I sell so many of these around Xmas time, I just make them myself with scissors and electric tape.

  • ximtor@lemm.ee
    link
    fedilink
    arrow-up
    32
    ·
    edit-2
    2 days ago

    No idea how and why but my dad once had a cable like that in his workshop.

    Short story: we were having a party, bit drunk and wanted power for the bigger speakers, needed an extension, rummaged around and found this one. Of course didn’t check the ends, plugged it in and then thought “oh what a weird male adapter there, lets take it…bzzzzt”.

    Have a tiny burn scar on my hand now, luckily nothing else happened. The cable got dismantled afterwards, but I still don’t know why it was there in the first place, he is a pretty good handyman normally.

    • qjkxbmwvz@startrek.website
      link
      fedilink
      arrow-up
      14
      ·
      2 days ago

      If you lose power, you can use one of these cables to power your house (or at least, the part of your house on that phase).

      This is not how you should do this, but it can work. It is not a good idea (possibly illegal?).

      • kassiopaea@lemmy.blahaj.zone
        link
        fedilink
        arrow-up
        34
        ·
        2 days ago

        In my jurisdiction, backfeeding your house from a receptacle is very illegal. Transfer switches and interlock kits exist for a reason.

        For anyone wondering exactly why it’s a bad idea: Power from your generator can, if your house isn’t isolated from the grid, travel back into the utility lines and backward through the big transformer at the utility pole (so now it’s a few thousand volts again) and give an unsuspecting linesman a nasty surprise. People have died from this. It is a bad idea.

        • Taleya@aussie.zone
          link
          fedilink
          English
          arrow-up
          8
          ·
          edit-2
          2 days ago

          This is also why solar inverters in most countries MUST be able to ‘island’ (logically disconnect from grid) in order to run a battery.

          We don’t have a battery yet, so our inverter shuts down on grid loss. Frustrating as hell when there’s an outage on a sunny day, but i get it.

        • MothmanLives@lemdro.id
          link
          fedilink
          English
          arrow-up
          6
          arrow-down
          1
          ·
          2 days ago

          Seems like the power companies should be responsible for either checking there is no back feeding or provide those things for everyone then. (I’m still not advocating for you back feeding your home)

          • InputZero@lemmy.world
            link
            fedilink
            arrow-up
            13
            ·
            2 days ago

            You’d have to constantly test. Just because a lines worker tested that the line is dead five seconds ago doesn’t mean some idiot just plugged one of these in.

            They can work, you just need to disconnect your house first then use it. It’s also a good way to burn your house down. If something on the same circuit as the generator pulls more current than the wires in the walls are designed to take, because there’s no breaker in the way anymore it can catch fire.

          • Sludgeyy@lemmy.world
            link
            fedilink
            arrow-up
            16
            ·
            2 days ago

            You can’t check for back feeding.

            Cable coming from house to pole has no power. Electrician goes to hook up wire. Homeowner puts on generator. Electrician gets electrocuted.

            Yes the testing and hooking up could be a small window of time but a fraction of a second after testing is all it takes.

  • wjrii@lemmy.world
    link
    fedilink
    arrow-up
    84
    ·
    3 days ago

    I have heard there are ways to use these to back feed power from a generator into a house’s system, at least on one breaker, but by definition that bypasses the breaker panel, and the only safe way to use your generator for your house is with a proper cutover installed by an electrician. I can think of literally no other use for one of these cords, except maybe fixing your fuck up if you install Christmas lights backwards.

    So yeah, dumb, dumb idea.

    • A_Union_of_Kobolds@lemmy.world
      link
      fedilink
      arrow-up
      58
      arrow-down
      1
      ·
      edit-2
      2 days ago

      This is all reasonably accurate. Source: electrician, who worked at a supply store for a while. I’ve had people ask how to make all kinds of stupid cords.

      If you don’t know what you’re doing, don’t fool with electricity

        • A_Union_of_Kobolds@lemmy.world
          link
          fedilink
          arrow-up
          4
          ·
          edit-2
          2 days ago

          Oh I know.

          I’ve talked to them.

          Don’t do it. If you haven’t actually worked with an electrician for at least two or.three years, just leave the repairs and shit jobs for people like me.

          If you can’t explain why the white wire is incorrectly called a neutral in single-phase systems, don’t touch it.

      • A_Union_of_Kobolds@lemmy.world
        link
        fedilink
        arrow-up
        7
        ·
        edit-2
        2 days ago

        This is the real issue and why you need a modern transfer switch. Lineman is working on the transformer on the pole, “it’s fine we cut it off upstream and I checked” and BOOM anyway

    • The_Hideous_Orgalorg@sh.itjust.works
      link
      fedilink
      arrow-up
      22
      ·
      3 days ago

      My friend’s house does this with their generator. There is a lockout on the breaker, and the main must be off to move it and open the one that feeds the back porch where they tie the generator in. Once the breakers are cycled, they can plug the generator into the outlet on the porch, and it runs there, sheltered from the weather. When the main power is working again, they turn off the generator, remove the cord, disable the breaker, toggle the lockout bar, and turn the main back on. The particular outlet on the porch is useless when using grid power because of this setup.

      • gazter@aussie.zone
        link
        fedilink
        arrow-up
        12
        arrow-down
        1
        ·
        3 days ago

        So if it’s only for the generator, why is it wired as an outlet, not an inlet?

    • bluesheep@lemm.ee
      link
      fedilink
      arrow-up
      11
      ·
      3 days ago

      I’ve heard the Christmas lights one before too, but I never got it. How do (American) Christmas lights work that you’d need one of these cords?

      • ShawiniganHandshake@sh.itjust.works
        link
        fedilink
        arrow-up
        16
        ·
        3 days ago

        In North America, Christmas lights usually have a plug end and a socket end so you can connect multiple strings together in series.

        If you accidentally put the plug end at the top of the tree, it might be tempting to try to buy or make one of these cords so you don’t have to take the lights down and redo them.

        It is as dumb and lazy as it sounds.

        • bluesheep@lemm.ee
          link
          fedilink
          arrow-up
          14
          ·
          3 days ago

          So if I understand it correctly, if you were to use this “solution”, you’d leave live exposed prongs on one end of the lights, right?

          Cause that would make it even dumber than I had imagined lmao

          • wjrii@lemmy.world
            link
            fedilink
            arrow-up
            6
            ·
            2 days ago

            Yup. American Christmas lights basically ARE very thin extension cords with the bulbs (hopefully) wired in parallel. Back in the day they were pretty much all incandescent and in series, and a single burned out bulb meant everything went out and Junior got a joyous new holiday chore!

    • Random_Character_A@lemmy.world
      link
      fedilink
      arrow-up
      4
      ·
      3 days ago

      There are voltage converters (230V<->120V) that have female connectors in both ends. So if DIY guys are playing with tech from other continents.

  • N3Cr0@lemmy.world
    link
    fedilink
    arrow-up
    34
    ·
    3 days ago

    My granpa once assigned a master electrician to make an extension cord after he accidently cut the cable of his hedge trimmer. The electrician built him a male2male cord with the female part on the machine. My granpa almost got electrocuted. 🤦‍♂️

    • DerisionConsulting@lemmy.ca
      link
      fedilink
      English
      arrow-up
      47
      ·
      3 days ago

      People use them to make their generators power their homes, by adding power into an outlet.

      So, whatever time of year power outages are likely to happen in this area.

      • hansolo@lemm.ee
        link
        fedilink
        English
        arrow-up
        18
        ·
        3 days ago

        Holy shit, does that work?

        I’m only familiar with having a generator properly wired into the house system at the panel, not some electrical Uno Reverse.

        • yes, it would (possibly) work, but you’re likely to run into quite a few safety-related issues outside of using the suicide cord. the fact that you’re probably injecting power downstream from any RCD units or even any basic current breakers, leaving you open to electrocution, or worst case, fire. the other issue is if you dont isolate your home from the grid before doing thus, then when the grid comes back (and your generator is still… generating) there’s likly to be a loud bang and a dead generator, let alone the risks you put on any workmen who are working on the lines they are expecting to not be carrying current.

          TLDR; unless your hourse is specifically wired for this, and you have the necessary protections in place, just use an extension cord and plug your fridge directly into the generator. 🤷

        • JakenVeina@lemm.ee
          link
          fedilink
          English
          arrow-up
          19
          arrow-down
          1
          ·
          3 days ago

          I did it last week. We were out of power for about 30 hours. But I actually have a degree in Computer Engineering, and I did it with a friend who is a professional Electrician.

          It is indeed EXTREMELY dangerous. If you don’t know what you’re doing, or make a mistake, best case scenario, you fry your generator. Worst case, you electrocute a lineman from the power company, who isn’t expecting lines to be live when there’s an outage, because yes, if you feed power into your house, that will flow OUT of your house onto the main lines (to some extent), if you let it. You could end up trying to power your whole block on your little gas generator.

          We made sure both the indoor and outdoor main power shutoffs for the house were turned off, as well as all breakers. Then we unplugged the oven, and used that for the feed from the generator. Then we gradually re-activated breakers so as not to add too much load to the generator at once. Ultimately, we were able to run the whole house, except for the AC compressor, which the generator actually would have had enough power to run, but not to kick-start.

          The proper way to hook up a generator to feed your house is to install an “inlet” which is both nominatively and physically the opposite of an outlet: instead of holes going into a box, you have prongs sticking out of a box. Generally, it’ll be one of the big fat 4-pronged round cables, like what your oven might use. That’ll feed down to a large double-breaker, in the top-right slot of your breaker panel. That breaker stays off until you want to run a generator, and, to meet code, you have to also install a special bracket that prevents you from turning this breaker off without turning off the primary feed for the whole house. Still kinda dangerous, but they make those brackets surprisingly foolproof.

          • MelodiousFunk@slrpnk.net
            link
            fedilink
            arrow-up
            10
            ·
            3 days ago

            except for the AC compressor, which the generator actually would have had enough power to run, but not to kick-start.

            This sentence triggered my PTSD. Imagine, if you will, a world where executives insist that datacenter AC be put on UPS battery. A world where those same executives declare that a different datacenter is just fine running at 95% power capacity because “it’s not 100%.” A world where inrush current does not exist. Except it does exist, but all professional advice is ignored until there are consequences. And even after such consequences are realized, one of those same executives still tries to run his home sump pump off of a desktop UPS during a power outage, pops it immediately, then goes and gets another from the office, which also pops immediately.

            The sign in OP’s post will always be relevant somewhere.

        • RegalPotoo@lemmy.world
          link
          fedilink
          English
          arrow-up
          16
          ·
          edit-2
          3 days ago

          It does, but it’s super dangerous to do unless you have it wired up properly. Proper installations will use a special connector so you can’t plug anything else into that receptical, and will have it interlocked against the main breaker - you can’t plug anything in without disconnecting from the grid. The dangers of doing it amateur-hour are:

          • You now have a cable that you can unplug and have live ends exposed - which if you don’t realize is connected to an active generator is super dangerous, and even if you do one slip and you are now the ground conductor
          • If you connect the generator while still connected to the grid, your generator is almost certainly going to be out of phase. This will probably cause damage to your generator and anything else plugged in at the time
          • If you don’t have an interlock and run the generator while connected to the grid (say during a power outage) you will be back-feeding power into the grid. This is super dangerous for anyone coming to fix the outage, as things that they’ve isolated to fix can still end up being live

          Note that this interlock is also required if you have solar - although it’s usually in the form of an automatic breaker that will disconnect and put the circuit into “island mode” if it detects a loss of grid supply

        • Rivalarrival@lemmy.today
          link
          fedilink
          English
          arrow-up
          10
          ·
          3 days ago

          If you have to ask, don’t do it.

          The proper way to connect a generator is with a breaker panel interlock. This gives you a circuit breaker for the main, grid power; a second breaker for the generator; and an interlock device that only allows one of those two breakers to be active at any given time.

          Trying to use a suicide cable can get power into the house; disconnecting the main breaker would prevent the generator from back feeding the grid. However, the circuit you are plugging the breaker into is only rated to 15 or 20 amps, and you’re backfeeding it with a lot more. You can easily overload this circuit without actually blowing a breaker.

          There’s other problems as well: your house wiring is designed for two opposing hot, 110v phases. These are combined to provide 220v power to major appliances. Improperly backfeeding your wiring can potentially damage those major appliances.

          You are better off with a nice, heavy-duty extension cord than a half-assed suicide cable.

          • hansolo@lemm.ee
            link
            fedilink
            English
            arrow-up
            2
            ·
            3 days ago

            Lol, not going to do it. Been mildly electrocuted too many times to mess around with something like this.

            More so curious about the physics here, but I see it’s basically a roll of the dice that it does work and doesnt just fry everything.

    • doctordevice@lemmy.ca
      link
      fedilink
      arrow-up
      22
      ·
      3 days ago

      I’m gonna guess winter, hanging Christmas lights. People string up their lights and then realize far too late that they put two strands with female ends facing each other and instead of restringing they look for a male-to-male cord to bridge the gap.

      A little live wire shouldn’t stand in the way of holiday cheer, after all.

      • kassiopaea@lemmy.blahaj.zone
        link
        fedilink
        arrow-up
        1
        ·
        2 days ago

        That would immediately blow the fuse in the lights and/or start a fire if the two strands were on different circuits that happened to be on different electrical phases.

        While I wouldn’t doubt that some people are stupid enough to do that, it’s actually summer that it’s done the most for because of storms and power outages, and people learn that backfeeding is a thing (that you shouldn’t do unless you absolutely know what you’re doing).

        • doctordevice@lemmy.ca
          link
          fedilink
          arrow-up
          3
          ·
          2 days ago

          I appreciate a good “um actually” but this really is about Christmas lights. People really are stupid enough for this to be something posted specifically around December.

          As far as I can tell from a reverse image search this is the original. (Not linking to the other place, DM me if you want the link for some reason).

            • doctordevice@lemmy.ca
              link
              fedilink
              arrow-up
              1
              ·
              2 days ago

              Never underestimate stupidity. Though I do think it’s at least not normally people trying to connect two strands that are themselves already live. It’s normally people who are connecting several strands together and started at the end not plugged in with the male end poking out, not realizing that this means when they’re done stringing and go to plug in they’ve got the female end and no way to plug it in.

              Left facing the daunting task of completely undoing all the work they just did, they try to look for something to bridge the gap without thinking through to the danger.

  • Freshparsnip@lemm.ee
    link
    fedilink
    English
    arrow-up
    41
    ·
    3 days ago

    It is written in the book of Leviticus: “It shall be unclean for one end of an electric cord to match the other”

    • Canonical_Warlock@lemmy.dbzer0.com
      link
      fedilink
      English
      arrow-up
      32
      ·
      3 days ago

      Holy shit, this is what that part in the bible is actually about. People back then just didn’t know about electricity so they thought it was about gay people.

      • uuldika@lemmy.ml
        link
        fedilink
        arrow-up
        11
        ·
        3 days ago

        honestly tho. if the Torah is legit its advice should apply to the future too. haShem wouldn’t just have been writing to Moishe’s time.

  • rumba@lemmy.zip
    link
    fedilink
    English
    arrow-up
    6
    ·
    2 days ago

    Why not have the meters detect and control a disconnect. with all the solar generation around, someone’s gotta have a bad transfer switch somewhere.

    • Ydna@lemmy.world
      link
      fedilink
      arrow-up
      1
      ·
      1 day ago

      Arc-fault breakers are required by code as of now, and it would help this situation quote a bit. However millions of homes don’t have them installed so they’re more at risk.

    • MajorasMaskForever@lemmy.world
      link
      fedilink
      English
      arrow-up
      5
      arrow-down
      1
      ·
      2 days ago

      Reaction time

      In the US, using a cord like this will either be harmless or create effectively a dead short. Typical breakers will catch the latter but it will take tenths of a second for a breaker to react in which time the electricity could kill someone.

      Depending on circuit conditions a GFCI might intervene as well, they’re typically faster at reacting (needing a few milliseconds) but for a cable designed to handle full residential power, it’s still enough to kill a person in that small window of time

    • Captain Aggravated@sh.itjust.works
      link
      fedilink
      English
      arrow-up
      18
      ·
      2 days ago

      Some genius won’t pay attention to the orientation of a christmas light display while he’s putting them up, he’ll go to plug them in, and they’ll be the wrong way, so he’ll want an “adapter.”

    • CoopaLoopa@lemmy.dbzer0.com
      link
      fedilink
      arrow-up
      7
      ·
      2 days ago

      Connecting this to two plugs on the same circuit won’t short anything unless one of the outlets is wired incorrectly.

      They’re used to backfeed power to your house from a generator during power outages. Technically not legal to use, but most people aren’t going to pay $1k for a proper transfer switch. They come with the caveat of ‘not to be operated by fuckwits’ since you can kill a linesman if you don’t flip your main breaker before using them.

    • HereIAm@lemmy.world
      link
      fedilink
      arrow-up
      15
      ·
      3 days ago

      I will just regurgitate what I’ve heard. I think they are used in case power goes out and you have a generator. You need to disconnect from the power grid first, but it should then allow you to power tour house with the generator. It sounds more like a US thing.

      • jubilationtcornpone@sh.itjust.works
        link
        fedilink
        arrow-up
        13
        ·
        2 days ago

        Yes, this would technically work. Although, it would only power the hot leg the outlet is connected to which only feeds part of the house.

        It’s very dangerous for a variety of reasons. Especially if you forget to shut off the mains breaker. The transformer can backfeed power down the line at line voltages, creating a shock hazard for lineman or anyone else who might have contact with the line.

        • LH0ezVT@sh.itjust.works
          link
          fedilink
          arrow-up
          2
          ·
          2 days ago

          Wouldn’t any repair worker ground anything they work on first, or assume it is live? I am not even a proper electrician, but “short-circuited and grounded, or treat it as live” has been the rule forever.

          • originaltnavn@lemm.ee
            link
            fedilink
            arrow-up
            12
            ·
            2 days ago

            Not an electrician, but I would imagine the danger being if the technician checked the wire was off locally, started work and then the home generator starts feeding mid work.

    • sugarfoot00@lemmy.ca
      link
      fedilink
      English
      arrow-up
      7
      ·
      3 days ago

      The only time I’ve ever seen one in use was a friend that had a shed that was powered with lights etc. He had an external plug box on the shed, and would use one of these to jumper from his extension cord to that external plug. It worked, but I shuddered when I saw it.

      • scrion@lemmy.world
        link
        fedilink
        arrow-up
        9
        ·
        2 days ago

        … and you could easily fix the whole situation by having the shed run a male extension cord out that could be plugged into the generator.

        It would also be infinitely more whimsical, since it’d make the shed look like a little appliance with its own chord. Or paint everything and call it a tail, the possibilities are endless.

        “Well, let me just plug in the shed real quick”

    • muse@lemmy.blahaj.zone
      link
      fedilink
      arrow-up
      1
      ·
      edit-2
      2 days ago

      I saw an electrician use one for troubleshooting. Half the outlets in the house were in serial on the same circuit, and there was a problem in the wall somewhere. He disconnected the wires from the breaker and backfed power from a live circuit to an outlet to see if there were any more breaks further away.

  • spacesatan@leminal.space
    link
    fedilink
    English
    arrow-up
    15
    arrow-down
    1
    ·
    3 days ago

    They cant stop you from buying heat shrink and wire strippers. Don’t let nothing hold you back